CoolTop

CoolTop

CoolTop represents a family of precision cooling units specifically designed for installation on top of IT racks in server rooms and large data centers. An ideal cooling system for Conteg-contained IT rack aisles. Unique solution for IT environments without occupied floor area in data centers.

SUITABLE FOR:

  • Any type of data center
  • Applications with large amounts of floor space
  • Clients focused on saving energy

 

MAIN FEATURES:

Effective use of data center floor space

  • Cooling systems with Cooltop units occupy zero floor area
  • Raised floor unneccesary for air distribution

Very low power consumption

  • Set of highly-efficient fans with EC technology motors
  • Perfect airflow control
  • Optimized heat exchanger and interior aerodynamics
  • Recommended pressure control

Perfect project adaptability

  • Easy grouping of CoolTop units to meet requested capacities
  • Ideal for contained hot or cold aisles

 

Where to buy
Print Favorities E-mail Twitter RSS
  • CoolTopCoolTopCoolTopCoolTop2CoolTop2CoolTop3
 CoolTeg Plus CW
    CoolTop2 CoolTop3
Indoor unit code Unit AC-TOP2-CW-240/60 AC-TCW-42-30/XX-XXX
Connected outdoor unit code   Chilled water system
BASIC DATA
Cooling system Chilled water
Architecture Open Open
Nominal cooling capacity1 kW 37.0 48.0
Nominal net cooling capacity2 kW 36.3 46.9
Power supply V/ph/Hz 230/1/50
Running current A 3.4 5.0
Maximum current A 4.6 6.8
Nominal power consumption W 710 1100
Nominal airflow3 m3/h 7700 11000
Number of fans Pcs 2 3
Motor fan technology EC
Water flow kg/h 6200 8200
Filter class G2 (+ droplet separator)
DIMENSIONS
Height4 mm (U) 600
Width mm 2400
Depth6 mm 400 (600)
Weight6 kg 175 184
PIPING CONNECTION
Supply pipe diameter and type 6/4" female
Return pipe diameter and type 6/4" female

1 Cooling capacity can be changed via electronic controller. Nominal cooling capacity is stated for airtemperature of 35 °C in hot zone, without condensation (relative humidity under dew point). Watertemperature is 10/15 °C, clean filters.

2 Net cooling capacity (without heat from fans) is usable cooling capacity of entire system

3 Airflow is changed by control needs. Nominal airflow equals nominal cooling capacity.

4 Without any base frame

5 Bottom side length 400 mm; top side length 600 mm

6 For weight with droplet separator, add 11 kg

File type Language version

  • Cooling Brochure (PDF - 0.59MB)
    de  en  fr  ru   
  • Technical Datasheet CoolTop (PDF - 1.29MB)
    cs  de  en  fr  ru   
  • Datasheet CoolTop (PDF - 0.54MB)
    en   

Datasheet:

Datasheet_CoolTop